155 research outputs found

    335 Placebo Effects In Laser‐Evoked Pain Potentials

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/90215/1/S1090-3801_06_60338-8.pd

    Psychophysical or spinal reflex measures when assessing conditioned pain modulation?

    Get PDF
    Background: Assessing conditioning pain modulation (CPM) with spinal reflex measures may produce more objective and stable CPM effects than using psychophysical measures. The aim of the study was to compare the CPM effect and test–retest reliability between a psychophysical protocol with thermal test‐stimulus and a spinal reflex protocol with electrical test‐stimulus. Methods: Twenty‐five healthy volunteers participated in two identical experiments separated by minimum 1 week. The thermal test‐stimulus was a constant heat stimulation of 120 s on the subjects’ forearm with continuous ratings of pain intensity on a 10 cm visual analogue scale. The electrical test‐stimulus was repeated electrical stimulation on the arch of the foot for 120 s, which elicited a nociceptive withdrawal reflex recorded from the anterior tibial muscle. Conditioning stimulus was a 7°C water bath. Differences in the magnitude and test–retest reliability were investigated with repeated‐measures analysis of variance and by relative and absolute reliability indices. Results: The CPM effect was −46% and 4.5% during the thermal and electrical test‐stimulus (p < 0.001) respectively. Intraclass correlation coefficient of 0.5 and 0.4 was found with the electrical and thermal test‐stimulus respectively. Wide limits of agreement were found for both the electrical (−3.4 to 3.8 mA) and the thermal test‐stimulus (−3.2 to 3.6 cm). Conclusions: More pronounced CPM effect was demonstrated when using a psychophysical protocol with thermal test‐stimulus compared to a spinal reflex protocol with electrical test‐stimulus. Fair relative reliability and poor absolute reliability (due to high intraindividual variability) was found in both protocols. Significance: The large difference in CPM effect between the two protocols suggests that the CPM effect relates to pain perception rather than nociception on the spinal level. Due to poor absolute intrarater reliability, we recommend caution and further research before using any of the investigated CPM protocols in clinical decision making on an individual level

    Comparing the costs and outcomes of an integrated twin compression screw (ITCS) nail with standard of care using a single lag screw or a single helical blade cephalomedullary nail in patients with intertrochanteric hip fractures

    Get PDF
    © 2018 The Author(s). Background: Surgical treatment is the optimal strategy for managing intertrochanteric fractures as it allows for early rehabilitation and functional recovery. The purpose of the study was to assess the cost-effectiveness of commonly used cephalomedullary nails for the treatment of unstable intertrochanteric hip fractures. Methods: A decision analytic model was developed from a US payer's perspective using clinical data from a pairwise meta-analysis of randomised controlled trials (RCTs) and comparative observational studies comparing the integrated twin compression screw (ITCS) nail versus two single-screw or blade cephalomedullary nails [single lag screw (SLS) nail and single helical blade (SHB) nail]. The model considered a cohort of 1000 patients with a mean age of 76, as reported in the clinical studies over a 1-year time period. Cost data was obtained from the Center for Medicare and Medicaid Services website and published literature and adjusted for inflation. One-way and probabilistic sensitivity analyses were conducted to assess the effect of uncertainty in model parameters on model conclusions. Results: The model estimated 0.546 quality-adjusted life years (QALYs) and 0.78 complications avoided by using the ITCS nail and 0.455 QALYs and 0.67 complications avoided for the standard of care, using SLS or SHB nails. The cost per patient was 34,336forpatientstreatedwithanITCSnailand34,336 for patients treated with an ITCS nail and 37,036 for patients treated with the standard of care respectively, resulting in a cost saving of 2700infavouroftheITCSnail.MoresavingswereobservedwhentheITCSnailwascomparedtotheSHB(2700 in favour of the ITCS nail. More savings were observed when the ITCS nail was compared to the SHB (3280 per patient) and SLS ($1652 per patient). The findings were robust to a range of both one-way and the probabilistic sensitivity analyses. Conclusion: In conclusion, the ITCS nail can be considered a cost saving intervention in patients undergoing intertrochanteric fracture fixation with an intramedullary device. Clinicians and policy makers should be encouraged to adopt healthcare technologies such as ITCS that will help them to provide quality healthcare despite falling budgets

    Lumbar position sense acuity during an electrical shock stressor

    Get PDF
    BACKGROUND: Optimal motor control of the spine depends on proprioceptive input as a prerequisite for co-ordination and the stability of the spine. Muscle spindles are known to play an important role in proprioception. Animal experiments suggest that an increase in sympathetic outflow can depress muscle spindle sensitivity. As the muscle spindle may be influenced by sympathetic modulation, we hypothesized that a state of high sympathetic activity as during mental stress would affect the proprioceptive output from the muscle spindles in the back muscles leading to alterations in proprioception and position sense acuity. The aim was to investigate the effect of mental stress, in this study the response to an electrical shock stressor, on position sense acuity in the rotational axis of the lumbar spine. METHODS: Passive and active position sense acuity in the rotational plane of the lumbar spine was investigated in the presence and absence of an electrical shock stressor in 14 healthy participants. An electrical shock-threat stressor lasting for approximately 12 minutes was used as imposed stressor to build up a strong anticipatory arousal: The participants were told that they were going to receive 8 painful electrical shocks however the participants never received the shocks. To quantify the level of physiological arousal and the level of sympathetic outflow continuous beat-to-beat changes in heart rate (beats*min(-1)) and systolic, diastolic and mean arterial blood pressure (mmHg) were measured. To quantify position sense acuity absolute error (AE) expressed in degrees was measured. Two-way analysis of variance with repeated measurements (subjects as random factor and treatments as fixed factors) was used to compare the different treatments. RESULTS: Significant increases were observed in systolic blood pressure, diastolic blood pressure, and heart rate during the stress sessions indicating elevated sympathetic activity (15, 14 and 10%, respectively). Despite pronounced changes in the sympathetic activity and subjective experiences of stress no changes were found in position sense acuity in the rotational plane of the lumbar spine in the presence of the electrical shock stressor compared to the control period. CONCLUSION: The present findings indicate that position sense acuity in the rotational plane of the spine was unaffected by the electrical shock stressor

    The syndrome of central hypothyroidism and macroorchidism: IGSF1 controls TRHR and FSHB expression by differential modulation of pituitary TGFβ and Activin pathways

    Get PDF
    IGSF1 (Immunoglobulin Superfamily 1) gene defects cause central hypothyroidism and macroorchidism. However, the pathogenic mechanisms of the disease remain unclear. Based on a patient with a full deletion of IGSF1 clinically followed from neonate to adulthood, we investigated a common pituitary origin for hypothyroidism and macroorchidism, and the role of IGSF1 as regulator of pituitary hormone secretion. The patient showed congenital central hypothyroidism with reduced TSH biopotency, over-secretion of FSH at neonatal minipuberty and macroorchidism from 3 years of age. His markedly elevated inhibin B was unable to inhibit FSH secretion, indicating a status of pituitary inhibin B resistance. We show here that IGSF1 is expressed both in thyrotropes and gonadotropes of the pituitary and in Leydig and germ cells in the testes, but at very low levels in Sertoli cells. Furthermore, IGSF1 stimulates transcription of the thyrotropin-releasing hormone receptor (TRHR) by negative modulation of the TGFβ1-Smad signaling pathway, and enhances the synthesis and biopotency of TSH, the hormone secreted by thyrotropes. By contrast, IGSF1 strongly down-regulates the activin-Smad pathway, leading to reduced expression of FSHB, the hormone secreted by gonadotropes. In conclusion, two relevant molecular mechanisms linked to central hypothyroidism and macroorchidism in IGSF1 deficiency are identified, revealing IGSF1 as an important regulator of TGFβ/Activin pathways in the pituitary
    corecore